Skip to content
AirVitalize

Radon fan replacement cost

Price a fan swap as a DIY job or a mitigator call-out, check whether the fan has really failed, and match the replacement so suction does not drop.

Step 1: Where is the house?

Adjusts the mitigator's labor. The fan itself is priced nationally.

Optional. Used only if no state is chosen. Stays in your browser.

Step 2: Where is the fan?

Fans must sit outside the living space: on an outside wall, in the garage or in the attic.

Step 3: Who will swap it?

In states that license mitigators, a homeowner may usually work on their own home, but a contractor must be credentialed.

Step 4: Replace anything else?

Your fan replacement estimate

US national average, 2026. Mitigator call-out.

Itemized estimate
ItemLow to high
Replacement radon fanSame model or a model with the same pressure and flow curve. Read the label on the old fan first.$150 to $280
Mitigator labor, fan on an outside wallSwap, reseal the couplings, check the manometer reading and confirm the discharge point.$150 to $275
Short-term radon retest kitRun it at least 24 hours after the new fan starts.$15 to $35

Where the money goes

Estimated total$315 to $590

Fans typically last 5 to 10 years running nonstop.

Compared with $315 to $590 for the job you described. Stays in your browser.

Compare local licensed contractors
Typical fan life
5 to 10 years
Fan only, retail
$150 to $280
Labor adjustment
None applied

Quote sanity-checker

A fan swap is quick and cheap. The mistakes that cost money are replacing a fan that was not the problem, and fitting a smaller fan than the system needs.

  • Is the fan really dead?

    Check the U-tube manometer on the pipe. If both columns are level at zero, the fan is not pulling suction. Before buying a fan, confirm the breaker or outlet is live and the disconnect switch is on.

  • Listen for bearing noise

    A fan that hums without spinning, grinds, rattles or squeals is near the end. Most fans fail between 5 and 10 years of continuous running.

  • Match the model, not just the pipe size

    Fans with the same pipe size can have very different pressure curves. Read the label and replace like for like, for example a RadonAway RP145 with an RP145 or its listed successor. A weaker fan may leave parts of the slab without enough suction.

  • Retest after the swap

    Run a short-term radon test at least 24 hours after the new fan starts, in the lowest lived-in level. The manometer shows the fan works; only a test shows the radon level.

Show 2 more things to check
  • Manometer reading changed a lot?

    A much higher reading than before can mean a blocked pipe or ice at the discharge. A much lower one can mean a leak at a coupling. Note the reading on the gauge so the next check has a baseline.

  • Water in the fan

    Condensate draining back into the fan housing shortens its life. Ask whether the pipe is sloped back toward the suction point.

Pricing a whole new system instead? Use the radon mitigation cost calculator.

Radon fan replacement, US national average

$315 to $590

See breakdown

No system yet, or the system never worked?

A fan swap fixes a system that used to work. To price a new system or a redesign with more suction points, use the radon mitigation cost calculator.

2026 prices at a glance

JobEstimated total
DIY swap, parts and retest kit$185 to $365
Mitigator, fan on an outside wall$315 to $590
Mitigator, fan in the garage$315 to $615
Mitigator, fan in the attic$365 to $665

Diagnosing a failing fan

  1. Read the manometer. The U-tube gauge on the pipe shows suction. Level liquid on both sides means no suction. Compare with the reading marked when the system was installed.
  2. Check power. Confirm the breaker, the outlet or the disconnect switch near the fan before you assume it has died.
  3. Listen. A healthy fan makes a steady low hum. Grinding, squealing, rattling or a hum with no airflow at the discharge point means the bearings or motor are going.
  4. Check the age. Fans run 24 hours a day and typically last 5 to 10 years. The install date is often written on the pipe or the fan label.

Matching the replacement fan

Read the model on the old fan's label and replace like for like. Radon fans are rated by how much flow they move at a given suction, and models with the same 4-inch or 6-inch connection can differ a lot. A RadonAway RP145, a common 4-inch fan for typical basements and slabs, should be replaced with an RP145 or the manufacturer's listed successor, and an RP265 with an RP265. Fitting a weaker fan to save money can leave part of the slab without enough vacuum, and the radon level will creep back up.

If the original system never brought the level down far enough, the fix may be a stronger fan or another suction point. That is a design question for a certified mitigator, not a straight swap.

Watching the system between tests

A manometer shows whether the fan is pulling suction; it does not measure radon. A continuous radon monitor shows the level in the house day to day, so you notice when a fan fails without waiting for the next test. Monitors compared below.

Common questions

How much does it cost to replace a radon fan?

A mitigator typically charges $315 to $590 to swap a fan on an outside wall, including the fan and a retest kit, at the national average. Attic fans cost a little more. Doing it yourself costs about $185 to $365 in parts.

How long does a radon fan last?

Radon fans run continuously and typically last 5 to 10 years. Many carry a five-year manufacturer warranty, so check the install date before paying for a new one.

How do I know my radon fan has stopped working?

Look at the U-tube manometer on the pipe. If the liquid is level on both sides, the fan is not pulling suction. A fan that hums without spinning, grinds or rattles is failing. Check the breaker and switch first.

Can I replace a radon fan myself?

Often, yes, on your own home: it is usually two rubber couplings and a power connection. Match the model, keep the fan outside the living space, and retest afterward. In states that license mitigators, anyone doing it for pay must hold the state credential.

Which replacement fan should I buy?

The same model, or the manufacturer's listed replacement for it. Fans with the same pipe size can have very different suction. Swapping a RadonAway RP145 for a smaller fan can leave parts of the slab without enough vacuum.