Radon mitigation cost in New Hampshire
EPA places one New Hampshire county in Zone 1, the highest-potential category. The calculator below is set to New Hampshire labor rates.
Prices, rules and sources last reviewed . How we check
Your radon estimate
New Hampshire, 2026. 1 suction point assumed.
| Item | Low to high |
|---|---|
| Active sub-slab depressurization (ASD) base installFan, PVC vent stack, one suction point, slab sealing, system label. | $850 to $1,575 |
| Electrical circuit prepOutlet or hard-wired connection and a disconnect within sight of the fan. | $100 to $325 |
| Post-mitigation verification testLow end is a mail-in lab kit; high end is an independent professional test. | $25 to $250 |
Where the money goes
Running cost: $57 to $158 a year in fan electricity.
Compared with $975 to $2,150 for the job you described. Stays in your browser.
The link holds your choices, not your ZIP code.
- EPA zone context
- New Hampshire: Mostly Zone 2
- Labor adjustment
- ×1.05 vs. national
- Fan replacement
- $300 to $600 every 5 to 10 yrs
At or above the EPA action level of 4.0 pCi/L
EPA recommends fixing the home at this level. If the result came from one short-term test, EPA advises a follow-up test to confirm before installing.
Quote sanity-checker
A quote well below $975 usually leaves something out. These 4 items matter most for the house you described.
Electrical disconnect and wiring
Is the outlet or hard-wired disconnect at the fan in the price, and is a licensed electrician doing it where your state requires one?
U-tube manometer
A U-tube manometer or other pressure indicator on the pipe shows at a glance that the fan is pulling vacuum. It should be standard, not an extra.
Post-install test
Who runs the verification test, and when? It should start no sooner than 24 hours after the system is switched on and within 30 days of install.
Sump pit sealing
If you have a sump, is a gas-tight cover in the quote? An open sump leaks soil gas and weakens the system.
Show 7 more things to check
Attic or exterior PVC routing
Which route is quoted? Interior routing through a closet or garage to the attic costs more but hides the pipe and protects the fan. Exterior routing is cheaper and visible.
Fan location
The fan belongs outside the living space — attic, garage or exterior — never in the basement or a crawl space, so a leak on the pressure side cannot vent indoors.
Discharge point
Exhaust should end above the roof edge and away from windows and other openings. Ask where exactly it terminates.
Number of suction points
How many suction points are in the price, and what does one more cost if the diagnostic test shows the first is not enough?
Crawl space membrane
Is sealing the crawl space floor with a membrane included, and how are seams and piers sealed?
Guaranteed result and warranty
What radon level does the installer guarantee (below 4.0 pCi/L, or lower), for how long, and what is the fan warranty?
Permit and credential
Does your town need a permit, and is the fee in the price? Ask for the installer's state license or NRPP/NRSB certification number.
Radon mitigation, New Hampshire
$975 to $2,150
New Hampshire prices compared with the national range
We adjust labor-heavy lines for New Hampshire by a factor of 1.05, about 5% above the national midpoint. Figures are for a 1,500 sq ft footprint with electrical prep and a verification test, and no add-ons.
| Foundation | New Hampshire | National |
|---|---|---|
| Unfinished basement | $975 to $2,150 | $925 to $2,050 |
| Finished basement | $1,175 to $2,675 | $1,125 to $2,550 |
| Slab-on-grade | $1,075 to $2,475 | $1,025 to $2,350 |
| Crawl space (dirt floor), membrane included | $2,125 to $5,050 | $2,025 to $4,800 |
| Combination | $1,700 to $3,200 | $1,625 to $3,050 |
What moves the price in New Hampshire
- Homes with open basements usually need a single suction point, which keeps most jobs near the low end.
- Labor runs a little above the national midpoint.
- Check the certification before you sign, and get the post-mitigation test result in writing.
New Hampshire licensing and certification
New Hampshire law (RSA 310-A:189-a) requires anyone who designs or installs a radon mitigation system to hold NRPP or NRSB certification. There is no separate state radon license.
- Regulating agency
- New Hampshire Department of Health and Human Services, Radon Program
- Ask to see
- NRPP or NRSB mitigation certification
- NRPP or NRSB certification
- Required by state law; there is no separate state license
- Law
- N.H. Rev. Stat. § 310-A:189-a
Rules change. Confirm current requirements and look up a contractor's credential with the New Hampshire radon program before you sign.
EPA Zone 1 counties in New Hampshire
EPA Zone 1 counties have a predicted average indoor screening level above 4 pCi/L. In New Hampshire they are:
- Carroll County
See EPA's Map of Radon Zones for every county. EPA says the map should not be used to decide whether to test: homes in Zone 2 and Zone 3 counties can also have high radon.
Already have a system?
Radon fans run around the clock and typically last 5 to 10 years. If the manometer reads zero or the fan has started to grind, see the radon fan replacement cost estimator.
Other states
- Alabama
- Alaska
- Arizona
- Arkansas
- California
- Colorado
- Connecticut
- Delaware
- District of Columbia
- Florida
- Georgia
- Hawaii
- Idaho
- Illinois
- Indiana
- Iowa
- Kansas
- Kentucky
- Louisiana
- Maine
- Maryland
- Massachusetts
- Michigan
- Minnesota
- Mississippi
- Missouri
- Montana
- Nebraska
- Nevada
- New Jersey
- New Mexico
- New York
- North Carolina
- North Dakota
- Ohio
- Oklahoma
- Oregon
- Pennsylvania
- Rhode Island
- South Carolina
- South Dakota
- Tennessee
- Texas
- Utah
- Vermont
- Virginia
- Washington
- West Virginia
- Wisconsin
- Wyoming
For how systems work and how to compare quotes, see the main radon mitigation cost guide.
New Hampshire radon questions
How much does radon mitigation cost in New Hampshire?
A typical New Hampshire install on a 1,500 sq ft footprint runs $975 to $2,150 including electrical prep and a verification test. Labor in New Hampshire is about 5% above the national midpoint. Larger footprints, crawl spaces and extra suction points cost more.
Do radon mitigators need a license in New Hampshire?
New Hampshire law (RSA 310-A:189-a) requires anyone who designs or installs a radon mitigation system to hold NRPP or NRSB certification. There is no separate state radon license.
Which New Hampshire counties are EPA Zone 1?
EPA Zone 1 counties in New Hampshire are Carroll. Homes outside Zone 1 can still test high, so EPA advises testing every home.
What is the EPA action level?
EPA recommends fixing a home at 4.0 pCi/L or higher and considering a fix between 2.0 and 4.0 pCi/L.